LCMS-2010EV (Evolution) refined and enhanced for even higher sensitivity
in mass spectrometry detection.
Key features
- Revised ion source design. Orthogonal source geometry with
an additional drying gas at the inlet of the capillary. Results
in higher sensitivity and greater control of solvent adduct formation.
- Revised electrospray probe design. Maintenance free design.
- Revised ion optics. Enhanced ion transmission by further optimising
the skimmer cone design at the entrance to the mass analyser.
- Microbore compatibility for both ESI and APCI. Technological
advances in probe design have expanded the operating range of
both APCI and ESI without affecting sensitivity. APCI is now
compatible with microbore flow rates (less than 50uL/minute)
while ESI can operate with flow rates as high as 2mL/minute without
requiring flow splitting
- Mass directed purification support. PsiPort™ mass directed
auto-purification software has been designed to help accelerate
compound isolation and auto-purification by preparative LC/MS.
The application software is web-based providing a generic solution
to data review and data acquisition and has been designed to
meet the needs of medicinal and synthetic chemists to track samples,
fractions and associated data from MS and UV detectors. PsiPort™ also
supports third party devices such as the Gilson 215 either as
a fraction collector or autosampler.
- Fast scanning electronics support 6000 amu/second (6000 data
points per second) acquisition rates for fast chromatography
applications. Peak widths of several seconds may be detected
using fast scan rates to maintain spectrum quality without affecting
the accuracy and precision of detection.
- Multi-sequence mode support. Supports mixed mode analysis
(switching between full scan acquisitions and selected ion monitoring),
multiple acquisition conditions in a single analysis, simultaneous
structural information and molecular weight confirmation in both
positive and negative ion mode from a single injection and optimizes
the response to both quantitation ions and confirmatory ions
to minimize false positives and increase confidence in peak assignment.
- Automatically controlled nebulizer gas flow.
- Software-controlled syringe pump for simple calibration and
infusion.
Unique Q-array™ (patent pending) ion guide. Q-array ion
guide (patent pending) configuration is unique - three quadrupoles
with different inscribed radii coupled with an octapole The Q-array™ precisely
focuses ion delivery into the mass analyser. The ion optic design
for the LCMS-2010EV is the most innovative design in ion focussing
technology. Using the Q-array™ (patent pending) and octapole
RF guides to precisely focus ions to the mass analyser we deliver
new limits of detection for LC.
Unmatched productivity
- Supports the new standard in high throughput auto-injectors,
the SIL-HT from Shimadzu (15 second injection cycle)
- Automatic acquisition, processing and reporting through a
single click of the mouse
High throughput micro-titre plate support. - Customised reporting for efficient and effective information
management.
- Streamlined data processing for third party software systems
- Automated export to knowledge systems.
- Mass directed purification.
Multi-sequence mode
- Enhanced source design
- The atmospheric pressure ion source now supports a counter
gas flow to control adduct formation and enhance ion transmission
of low polarity compounds. The counter gas flow not only enhances
the desolvation processes but reduces the maintenance on the
capillary inlet.
- To reduce maintenance further and increase sensitivity the
electrospray probe design has also been redesigned to take into
account a stainless steel capillary.
|