Shimadzu GC Driver for OpenLab CDS - Specs
Shimadzu GC Driver
Product Lineup
| Description | Version | Versions with Functionality Verified | 
|---|---|---|
| Shimadzu GC Driver Single for OpenLab CDS 2 | 2.30 | OpenLab CDS 2.5 / 2.6 / 2.7 | 
| Shimadzu GC Driver Single for OpenLab EZChrom | 2.30 | OpenLab EZChrom A.04.09, A.04.10 | 
• The same product is used both for standalone and network versions of OpenLab systems.
• To install the driver in an existing OpenLab system, please provide the version of applicable software and other relevant information in advance.
Controllable Hardware
| GC Unit | Nexis GC-2030, GC-2010 Plus, GC-2010, GC-2010 Pro, GC-2014, GC-2014C | 
|---|---|
| Options | AOC-30i autoinjector, AOC-20i (Plus) autoinjector, AOC-20s (U) autosampler, HS-20 (NX)/HS-10 headspace sampler, dual injection system | 
Nexis GC-2030
| Sample injector | SPL-2030, WBI-2030, OCI-2030, PTV-2030, SINJ-2030, OCI-2030NX | 
|---|---|
| Detector | FID-2030, TCD-2030, ECD-2010 Exceed, FPD-2030, FTD-2030, BID-2030, SCD-2030, PTCD-2030 | 
| Advanced flow technology | Backlash, detector splitting, detector switching, heart-cut system | 
| Additional temperature controller | Auxiliary temperature control unit | 
| Additional flow controller | APC (3 auxiliary channels), APC (1 auxiliary channel) | 
| Options | Gas Selector | 
• Up to four Shimadzu GC units can be controlled from a single computer or acquisition server (such as an AIC).
• Both the Shimadzu GC driver and Shimadzu LC driver can be installed on the same computer or acquisition server (such as an AIC).
• A Shimadzu GC system and Agilent GC system cannot be connected to the same computer or acquisition server (such as an AIC) at the same time.
Provide a data acquisition server dedicated for the Shimadzu GC system separately.
GC-2010 (Plus/Pro) and GC-2014 (C)
| Sample injector | GC-2010 (Plus/Pro): SPL-2010 (Plus), WBI-2010 (Plus), OCI/PTV-2010 (Plus) | 
|---|---|
| Detector | GC-2010 (Plus/Pro) : FID-2010 (Plus), TCD-2010 (Plus), ECD-2010 Exceed, ECD-2010 (Plus), FPD-2010 (Plus), FTD-2010 (Plus), BID-2010 Plus | 
| Additional temperature controller | Auxiliary temperature control unit | 
| Additional flow controller | APC (3 auxiliary channels), AMC (2 auxiliary channels) Note: AMC is an option for the GC-2014 | 
| Options | CRG-2010 low-temperature control solenoid valve set | 
• Up to four Shimadzu GC units can be controlled from a single computer or acquisition server (AIC etc.).
• Both the Shimadzu GC driver and Shimadzu LC driver can be installed on the same computer or acquisition server (AIC etc.).
• A Shimadzu GC system and an Agilent GC system cannot be connected to the same computer or acquisition server (AIC etc.) at the same time. Please provide a dedicated data acquisition server for the Shimadzu GC system.